KUKA 00-134-525 KPS-600/20-ESC power supply

KUKA 00-134-525 KPS-600/20-ESC power supply for KR C2 and KRC2ed05 controllers, with documented AC input and 600 V DC output.

Controller power role

Rebuilt from individual evidence

Electrical limits and evidence

DO Supply identifies KUKA 00-134-525 as a KPS-600/20-ESC power supply unit for the KRC2 line. MRO Electric independently lists the exact manufacturer, power-supply type and model number 00134525.

The documented electrical path accepts three-phase 380-480 V AC at 50/60 Hz and provides 600 V DC at up to 20 A, with a listed 36 kW rating, for KUKA KR C2 and KRC2ed05 controller systems.

Unknown: installation-specific cabinet wiring, protective devices, commissioning settings, controller revision compatibility, and the condition, revision, service history, warranty status or current availability of an individual unit.

Exact reference
00-134-525
Category
Robotics
Evidence checked
2026-09-11

System role

This section explains what the product does and where it acts in the surrounding system.

Function
Converts three-phase 380-480 V AC into a 600 V DC supply for KUKA KR C2 and KRC2ed05 robot controllers.
System position
Sits in the controller power path between the three-phase AC source and the KUKA controller's DC supply.
Upstream / inputs
Three-phase 380-480 V AC at 50/60 Hz is the documented upstream input.
Downstream / outputs
The module provides the documented 600 V DC output at up to 20 A to the compatible controller system.
Limitations
Unknown: installation-specific cabinet wiring, protective devices, commissioning settings, controller revision compatibility, unit condition, service history and availability.

Evidence ledger

Facts, inferences, and unknowns are kept separate.

Facts

  • DO Supply identifies 00-134-525 as the KUKA KPS-600/20-ESC power supply unit in the KRC2 product line.

    Confidence: medium

  • DO Supply lists three-phase 380-480 V AC input at 50/60 Hz, 600 V DC output, 20 A output current and a 36 kW power rating for 00-134-525.

    Confidence: medium

  • DO Supply lists compatibility with KUKA KR C2 and KRC2ed05 robot controllers.

    Confidence: medium

  • MRO Electric identifies the exact manufacturer as KUKA, the type as power supplies and the model number as 00134525.

    Confidence: medium

Inferences

  • Inferred system position: the module sits in the controller power path between the three-phase AC source and the KUKA controller's DC supply.

    Confidence: medium

    Rationale: The sources identify the exact module as a KUKA controller power supply and document its AC input and DC output.

  • Inferred function: the module converts the documented three-phase AC input into the 600 V DC supply used by the compatible KUKA controller system.

    Confidence: medium

    Rationale: The exact-reference technical listing states the conversion values and names the KUKA controller families it is designed to serve.

Unknowns

  • Unknown: installation-specific cabinet wiring, protective devices, commissioning settings and compatibility with a particular controller revision.

    Confidence: low

    Missing evidence: No installation drawing or controller revision-specific wiring evidence was captured.

  • Unknown: the condition, revision, service history, warranty status and current availability of an individual unit.

    Confidence: low

    Missing evidence: Distributor pages describe sales or repair services but do not establish the condition of a particular unit.

System position diagram

Three-phase AC enters KUKA 00-134-525, which provides documented 600 V DC output to a KR C2 or KRC2ed05 controller.

Reading limit: system position only, not a wiring or safety drawing.

The diagram shows the documented AC input, conversion role and controller association; installation-specific wiring remains unknown.

Enlarged system diagram

Three-phase AC enters KUKA 00-134-525, which provides documented 600 V DC output to a KR C2 or KRC2ed05 controller.

The diagram shows the documented AC input, conversion role and controller association; installation-specific wiring remains unknown.

View Mermaid source
flowchart LR
  ac["Three-phase 380-480 V AC"] -->|KPS-600/20-ESC conversion| supply["00-134-525 KUKA power supply"]
  supply -->|600 V DC, up to 20 A| controller["KR C2 or KRC2ed05 controller"]
View diagram labels
Nodes
Three-phase AC source; 00-134-525 KPS-600/20-ESC; KR C2 or KRC2ed05 controller
Edges
AC-to-DC conversion; 600 V DC, up to 20 A

Next action

The captured exact-reference evidence supports publishing 00-134-525 as a KUKA KPS-600/20-ESC controller power supply with documented electrical values and explicit installation unknowns.

Verify the complete 00-134-525 marking, controller family, cabinet wiring and protection design against the installation documentation before energizing or replacing the unit.

Request help with this reference

Request help with this reference

Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.

Submission is unavailable until durable storage is verified.

Recovery request details
Add context only if useful
Optional updates
Recipient and data disclosure

Recipient and data disclosure

Named recipient: Ardkor human-qualification queue (internal local preview). No partner delivery is enabled here.

Data retained for this review: reference, selected route, location, technical context, contact details, consent state, and any accepted private attachment.

Response expectation: none is promised. If external routing is enabled later, the partner name, disclosed fields, and response expectation must be shown and accepted again.

Withdrawal and deletion: use the private request controls from the receipt to withdraw further processing or request access/deletion. The request remains recorded until the relevant Ardkor systems and any recipient confirm completion.

Read the privacy information before sending. For corrections, access, or deletion help, use the contact page or email reference@ardkor.org; mailbox delivery and attendance have not been verified.

This routing state is separate from watch, marketing, payment, and analytics choices. If no capable service match is found, the request remains a human-qualification lead and is never presented as provider acceptance. Ardkor is not an emergency or safety service and submission does not guarantee availability, price, repair, sourcing, or response.