Rockwell Automation 2198-P031 Kinetix 5700 DC Bus Supply
An active 10 A, 480 V three-phase Kinetix 5700 DC bus supply for a shared motion power system.
System role
Rebuilt from individual evidence
Documented facts
Evidence limits
The Rockwell Automation product page identifies 2198-P031 as a Kinetix 5700 DC bus supply.
The manufacturer lists a 10 A DC bus supply, 480 V AC three-phase input and 55 mm width for this exact reference.
This DC bus supply converts three-phase AC input into the Kinetix 5700 common DC bus for connected inverter modules.
Unknown: installation-specific compatibility, firmware, wiring and unit condition.
- Exact reference
- 2198-P031
- Category
- Drives / VFD
- Evidence checked
- 2026-09-11
System role
This section explains what the product does and where it acts in the surrounding system.
- Function
- This DC bus supply converts three-phase AC input into the Kinetix 5700 common DC bus for connected inverter modules.
- System position
- It sits between upstream control or power and the downstream machine or network within the head of a Kinetix 5700 shared DC bus.
- Upstream / inputs
- It receives three-phase AC power and the system enable or safety state.
- Downstream / outputs
- It sends the common DC bus for connected Kinetix 5700 modules.
- Limitations
- Unknown: installation-specific compatibility, firmware, wiring and unit condition.
Evidence ledger
Facts, inferences, and unknowns are kept separate.
Facts
The Rockwell Automation product page identifies 2198-P031 as a Kinetix 5700 DC bus supply.
- www.rockwellautomation.com — retrieved 2026-09-11; high confidence
- device.report — retrieved 2026-09-11; high confidence
The manufacturer lists a 10 A DC bus supply, 480 V AC three-phase input and 55 mm width for this exact reference.
- www.rockwellautomation.com — retrieved 2026-09-11; high confidence
- device.report — retrieved 2026-09-11; high confidence
Inferences
This DC bus supply converts three-phase AC input into the Kinetix 5700 common DC bus for connected inverter modules.
- www.rockwellautomation.com — retrieved 2026-09-11; high confidence
- device.report — retrieved 2026-09-11; high confidence
Unknowns
Unknown: installation-specific compatibility, firmware, wiring and unit condition.
System position diagram
View Mermaid source
flowchart LR\n upstream[Upstream control or power] --> product[2198-P031]\n product --> downstream[Machine or network]View diagram labels
- Nodes
- Upstream control or power; 2198-P031; Machine or network
- Edges
- Upstream command or power path; Controlled output or status path
Request help with this reference
Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.