Siemens SIMATIC S7-1200 SB1221 221-3BD30-0XB0 Digital Input Board
A 24 VDC, four-channel high-speed digital input signal board for a SIMATIC S7-1200 CPU.
System role
Rebuilt from individual evidence
Documented facts
Evidence limits
Siemens TIA documentation identifies this exact reference as an SB1221 input board.
The Siemens technical specification describes four 24 VDC source inputs with high-speed counting support up to 200 kHz.
This signal board receives 24 VDC digital field signals and passes them into the S7-1200 CPU.
Unknown: installation-specific compatibility, firmware, wiring and unit condition.
- Exact reference
- 221-3BD30-0XB0
- Category
- PLC / CPU
- Evidence checked
- 2026-09-11
System role
This section explains what the product does and where it acts in the surrounding system.
- Function
- This signal board receives 24 VDC digital field signals and passes them into the S7-1200 CPU.
- System position
- It sits between upstream control or power and the downstream machine or network within the S7-1200 CPU signal-board input position.
- Upstream / inputs
- It receives switching signals from sensors or other 24 VDC field devices.
- Downstream / outputs
- It sends sampled input states to the CPU process image.
- Limitations
- Unknown: installation-specific compatibility, firmware, wiring and unit condition.
Evidence ledger
Facts, inferences, and unknowns are kept separate.
Facts
Siemens TIA documentation identifies the full article 6ES7 221-3BD30-0XB0, whose exact reference suffix is 221-3BD30-0XB0, as an SB1221 input board.
- docs.tia.siemens.cloud — retrieved 2026-09-11; high confidence
- support.industry.siemens.com — retrieved 2026-09-11; high confidence
The Siemens technical specification describes four 24 VDC source inputs with high-speed counting support up to 200 kHz.
- docs.tia.siemens.cloud — retrieved 2026-09-11; high confidence
- support.industry.siemens.com — retrieved 2026-09-11; high confidence
Inferences
This signal board receives 24 VDC digital field signals and passes them into the S7-1200 CPU.
- docs.tia.siemens.cloud — retrieved 2026-09-11; high confidence
- support.industry.siemens.com — retrieved 2026-09-11; high confidence
Unknowns
Unknown: installation-specific compatibility, firmware, wiring and unit condition.
System position diagram
View Mermaid source
flowchart LR\n upstream[Upstream control or power] --> product[221-3BD30-0XB0]\n product --> downstream[Machine or network]View diagram labels
- Nodes
- Upstream control or power; 221-3BD30-0XB0; Machine or network
- Edges
- Upstream command or power path; Controlled output or status path
Request help with this reference