3WL1110-3EB37-5FA4-ZR10 Siemens 3WL withdrawable air circuit breaker
Clean-room evidence identifies 3WL1110-3EB37-5FA4-ZR10 as Siemens 3WL withdrawable air circuit breaker. The exact reference is listed as a Siemens 3WL withdrawable three-pole circuit breaker, size I, rated 1000 A to 690 V, with 66 kA Icu at 500 V and rear vertical connections.
Documented identity and function
Rebuilt from individual evidence
System position
The exact reference is listed as a Siemens 3WL withdrawable three-pole circuit breaker, size I, rated 1000 A to 690 V, with 66 kA Icu at 500 V and rear vertical connections.
The exact listing specifies an ETU45 LSIN overcurrent release, adjustable 0.4-1 In protection, and motor or hand operation with 110-127 V AC or 110-125 V DC motor supply.
The system path is inferred as the low-voltage busbar or upstream source, then 3WL1110-3EB37-5FA4-ZR10, then the protected outgoing feeder.
Unknown: installation compatibility, configuration, and unit condition are not established by the captured sources.
- Exact reference
- 3WL1110-3EB37-5FA4-ZR10
- Category
- PLC / CPU
- Evidence checked
- 2026-09-11
System role
This section explains what the product does and where it acts in the surrounding system.
- Function
- The 3WL air circuit breaker protects and switches a high-current incoming or feeder circuit.
- System position
- It intervenes between the low-voltage busbar or upstream source and the protected outgoing feeder in the documented system path.
- Upstream / inputs
- Inputs or upstream: the low-voltage busbar or upstream source.
- Downstream / outputs
- Outputs or downstream: the protected outgoing feeder.
- Limitations
- Unknown: installation compatibility, configuration, and unit condition are not established by the captured sources.
Evidence ledger
Facts, inferences, and unknowns are kept separate.
Facts
The exact reference is listed as a Siemens 3WL withdrawable three-pole circuit breaker, size I, rated 1000 A to 690 V, with 66 kA Icu at 500 V and rear vertical connections.
- plc-trade.com — retrieved 2026-09-11; medium confidence
The exact listing specifies an ETU45 LSIN overcurrent release, adjustable 0.4-1 In protection, and motor or hand operation with 110-127 V AC or 110-125 V DC motor supply.
- plc-trade.com — retrieved 2026-09-11; medium confidence
Inferences
Inferred system position: 3WL1110-3EB37-5FA4-ZR10 intervenes between the low-voltage busbar or upstream source and the protected outgoing feeder.
- plc-trade.com — retrieved 2026-09-11; medium confidence
Unknowns
Unknown: installation compatibility, configuration, and unit condition are not established by the captured sources.
System position diagram
View Mermaid source
flowchart LR
U["Upstream"] --> P["3WL1110-3EB37-5FA4-ZR10"]
P --> D["Downstream"]View diagram labels
- Nodes
- Upstream: the low-voltage busbar or upstream source; Device: 3WL1110-3EB37-5FA4-ZR10; Downstream: the protected outgoing feeder
- Edges
- The upstream path feeds 3WL1110-3EB37-5FA4-ZR10.; 3WL1110-3EB37-5FA4-ZR10 feeds the downstream path.