4AM3442-8DD40-0FA0 Siemens SITAS control transformer

Clean-room evidence identifies 4AM3442-8DD40-0FA0 as Siemens SITAS control transformer. The Siemens data sheet identifies the exact reference as a one-phase SITAS transformer with 100 VA rated apparent power and 310 VA short-term power.

Documented identity and function

Rebuilt from individual evidence

System position

The Siemens data sheet identifies the exact reference as a one-phase SITAS transformer with 100 VA rated apparent power and 310 VA short-term power.

The data sheet lists selectable 208-550 V primary taps, 230 V or 115 V output, 0.435-0.87 A secondary current, 50-60 Hz operation, IP00, and screw or DIN-rail mounting.

The system path is inferred as the selectable 208-550 V primary distribution, then 4AM3442-8DD40-0FA0, then the 230 V or 115 V control circuit.

Unknown: installation compatibility, configuration, and unit condition are not established by the captured sources.

Exact reference
4AM3442-8DD40-0FA0
Category
PLC / CPU
Evidence checked
2026-09-11

System role

This section explains what the product does and where it acts in the surrounding system.

Function
The SITAS control transformer converts a selectable primary supply to an isolated single-phase control supply.
System position
It intervenes between the selectable 208-550 V primary distribution and the 230 V or 115 V control circuit in the documented system path.
Upstream / inputs
Inputs or upstream: the selectable 208-550 V primary distribution.
Downstream / outputs
Outputs or downstream: the 230 V or 115 V control circuit.
Limitations
Unknown: installation compatibility, configuration, and unit condition are not established by the captured sources.

Evidence ledger

Facts, inferences, and unknowns are kept separate.

Facts

  • The Siemens data sheet identifies the exact reference as a one-phase SITAS transformer with 100 VA rated apparent power and 310 VA short-term power.

    Confidence: high

  • The data sheet lists selectable 208-550 V primary taps, 230 V or 115 V output, 0.435-0.87 A secondary current, 50-60 Hz operation, IP00, and screw or DIN-rail mounting.

    Confidence: high

Inferences

  • Inferred system position: 4AM3442-8DD40-0FA0 intervenes between the selectable 208-550 V primary distribution and the 230 V or 115 V control circuit.

    Confidence: medium

    Rationale: The exact-reference sources identify the component function and its connected interfaces; the intervening system position is an inference from those facts.

Unknowns

  • Unknown: installation compatibility, configuration, and unit condition are not established by the captured sources.

    Confidence: low

    Missing evidence: No captured source provides the receiving system configuration, firmware, wiring, or unit condition.

System position diagram

Diagram showing 4AM3442-8DD40-0FA0 between the selectable 208-550 V primary distribution and the 230 V or 115 V control circuit.

Reading limit: system position only, not a wiring or safety drawing.

System path inferred from the documented function of 4AM3442-8DD40-0FA0.

Enlarged system diagram

Diagram showing 4AM3442-8DD40-0FA0 between the selectable 208-550 V primary distribution and the 230 V or 115 V control circuit.

System path inferred from the documented function of 4AM3442-8DD40-0FA0.

View Mermaid source
flowchart LR
  U["Upstream"] --> P["4AM3442-8DD40-0FA0"]
  P --> D["Downstream"]
View diagram labels
Nodes
Upstream: the selectable 208-550 V primary distribution; Device: 4AM3442-8DD40-0FA0; Downstream: the 230 V or 115 V control circuit
Edges
The upstream path feeds 4AM3442-8DD40-0FA0.; 4AM3442-8DD40-0FA0 feeds the downstream path.

Next action

Publishable as a clean-room evidence record for 4AM3442-8DD40-0FA0; verify the installation against current documentation.

Confirm voltage, wiring, accessories, and service condition against the installation before substitution.

Request help with this reference

Request help with this reference

Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.

Submission is unavailable until durable storage is verified.

Recovery request details
Add context only if useful
Optional updates
Recipient and data disclosure

Recipient and data disclosure

Named recipient: Ardkor human-qualification queue (internal local preview). No partner delivery is enabled here.

Data retained for this review: reference, selected route, location, technical context, contact details, consent state, and any accepted private attachment.

Response expectation: none is promised. If external routing is enabled later, the partner name, disclosed fields, and response expectation must be shown and accepted again.

Withdrawal and deletion: use the private request controls from the receipt to withdraw further processing or request access/deletion. The request remains recorded until the relevant Ardkor systems and any recipient confirm completion.

Read the privacy information before sending. For corrections, access, or deletion help, use the contact page or email reference@ardkor.org; mailbox delivery and attendance have not been verified.

This routing state is separate from watch, marketing, payment, and analytics choices. If no capable service match is found, the request remains a human-qualification lead and is never presented as provider acceptance. Ardkor is not an emergency or safety service and submission does not guarantee availability, price, repair, sourcing, or response.