Siemens 6ED1052-2HB08-0BA2 LOGO! 24RCEo logic module without display

Siemens 6ED1052-2HB08-0BA2 is documented for the stated industrial system role: Executes programmed LOGO! logic, processes eight digital inputs, switches four relay outputs, and exposes the documented Ethernet services.

System function

Rebuilt from individual evidence

System position

Siemens identifies 6ED1052-2HB08-0BA2 as LOGO! 24RCEo (AC), a logic module without a display with 24 V DC/24 V AC relay I/O.

Siemens lists 8 digital inputs, 4 relay outputs, 400-block memory, modular expansion, Ethernet, an integrated web server, data logging, microSD, and MQTT for the exact module.

Executes programmed LOGO! logic, processes eight digital inputs, switches four relay outputs, and exposes the documented Ethernet services.

The system position is an explicit inference from the exact-reference evidence.

Unknown: firmware level, loaded program, relay loading, network configuration, and installation-specific compatibility.

Exact reference
6ED1052-2HB08-0BA2
Category
PLC / CPU
Evidence checked
2026-09-12

System role

This section explains what the product does and where it acts in the surrounding system.

Function
Executes programmed LOGO! logic, processes eight digital inputs, switches four relay outputs, and exposes the documented Ethernet services.
System position
Sits between field I/O and relay-switched loads as a compact no-display LOGO! controller.
Upstream / inputs
Receives 24 V AC/DC power and the documented digital field signals.
Downstream / outputs
Switches four relay outputs and publishes controller data through Ethernet, web, data-log, and MQTT functions.
Limitations
Unknown: firmware level, loaded program, relay loading, network configuration, and installation-specific compatibility.

Evidence ledger

Facts, inferences, and unknowns are kept separate.

Facts

  • Siemens identifies 6ED1052-2HB08-0BA2 as LOGO! 24RCEo (AC), a logic module without a display with 24 V DC/24 V AC relay I/O.

    Confidence: high

  • Siemens lists 8 digital inputs, 4 relay outputs, 400-block memory, modular expansion, Ethernet, an integrated web server, data logging, microSD, and MQTT for the exact module.

    Confidence: high

Inferences

  • Inferred system position: Sits between field I/O and relay-switched loads as a compact no-display LOGO! controller.

    Confidence: high

    Rationale: The exact-reference sources establish the product identity and documented interfaces; their relationship to the stated upstream and downstream elements is marked as an inference.

Unknowns

  • Unknown: firmware level, loaded program, relay loading, network configuration, and installation-specific compatibility.

    Confidence: low

    Missing evidence: The individual lookup does not establish the installation, configured software, physical condition, or current commercial record.

System position diagram

A system diagram places Siemens 6ED1052-2HB08-0BA2 LOGO! 24RCEo logic module without display between Field sensors, switches, and 24 V AC/DC control supply and Relay-switched machine loads and Ethernet-connected supervisory tools; the placement is marked as an inference.

Reading limit: system position only, not a wiring or safety drawing.

The component placement between the documented upstream and downstream elements is an explicit inference.

Enlarged system diagram

A system diagram places Siemens 6ED1052-2HB08-0BA2 LOGO! 24RCEo logic module without display between Field sensors, switches, and 24 V AC/DC control supply and Relay-switched machine loads and Ethernet-connected supervisory tools; the placement is marked as an inference.

The component placement between the documented upstream and downstream elements is an explicit inference.

View Mermaid source
flowchart LR; Upstream-->Component; Component-->Downstream
View diagram labels
Nodes
Field sensors, switches, and 24 V AC/DC control supply; Siemens 6ED1052-2HB08-0BA2 LOGO! 24RCEo logic module without display; Relay-switched machine loads and Ethernet-connected supervisory tools
Edges
Input and control data; Processed output

Next action

Siemens primary catalog evidence supports the exact identity, control function, interfaces, and system position.

Confirm the target controller, wiring, configuration, and installation constraints before deployment or replacement.

Request help with this reference

Request help with this reference

Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.

Submission is unavailable until durable storage is verified.

Recovery request details
Add context only if useful
Optional updates
Recipient and data disclosure

Recipient and data disclosure

Named recipient: Ardkor human-qualification queue (internal local preview). No partner delivery is enabled here.

Data retained for this review: reference, selected route, location, technical context, contact details, consent state, and any accepted private attachment.

Response expectation: none is promised. If external routing is enabled later, the partner name, disclosed fields, and response expectation must be shown and accepted again.

Withdrawal and deletion: use the private request controls from the receipt to withdraw further processing or request access/deletion. The request remains recorded until the relevant Ardkor systems and any recipient confirm completion.

Read the privacy information before sending. For corrections, access, or deletion help, use the contact page or email reference@ardkor.org; mailbox delivery and attendance have not been verified.

This routing state is separate from watch, marketing, payment, and analytics choices. If no capable service match is found, the request remains a human-qualification lead and is never presented as provider acceptance. Ardkor is not an emergency or safety service and submission does not guarantee availability, price, repair, sourcing, or response.