Siemens 6EP1336-2BA00 SITOP POWER 20 supply

Siemens 6EP1336-2BA00 is a SITOP POWER 20 stabilized supply that converts 120/230 V AC to 24 V DC at 20 A.

System function

Rebuilt from individual evidence

Evidence and limits

6EP1336-2BA00 is documented as a SITOP POWER 20 stabilized supply with 120/230 V AC input and 24 V DC output at 20 A.

Its system position is the AC-to-DC conversion point that feeds an automation cabinet distribution path.

The captured data sheet lists a minimum 10 ms mains-buffering value.

Unknown: the installed cabinet load, wiring, ambient conditions, service status, and replacement compatibility.

Exact reference
6EP1336-2BA00
Category
PLC / CPU
Evidence checked
2026-09-12

System role

This section explains what the product does and where it acts in the surrounding system.

Function
Converts single-phase 120/230 V AC into a stabilized 24 V DC supply rated at 20 A.
System position
Sits between the incoming AC supply and the automation cabinet DC distribution.
Upstream / inputs
Single-phase 120/230 V AC feeds the power supply.
Downstream / outputs
The stabilized 24 V DC output feeds downstream cabinet control loads.
Limitations
Unknown: the installed cabinet load, wiring, ambient conditions, service status, and replacement compatibility.

Evidence ledger

Facts, inferences, and unknowns are kept separate.

Facts

  • The Siemens data sheet identifies 6EP1336-2BA00 as a SITOP POWER 20 stabilized power supply with 120/230 V AC input and 24 V DC/20 A output.

    Confidence: high

  • The data sheet specifies a single-phase AC input with 120 V and 230 V nominal values.

    Confidence: high

  • The data sheet specifies a 24 V DC output rated at 20 A.

    Confidence: high

  • The data sheet lists a minimum 10 ms mains-buffering value at rated output current.

    Confidence: high

Inferences

  • The supply sits between incoming single-phase AC and the automation cabinet DC distribution.

    Confidence: high

    Rationale: The documented AC input and stabilized DC output establish the conversion point in the cabinet power path.

Unknowns

  • Unknown: the installed cabinet load, wiring, ambient conditions, service status, and replacement compatibility.

    Confidence: low

    Missing evidence: No installation-specific cabinet, wiring, environmental, service, or replacement record was captured.

System position diagram

A 120/230 V AC supply feeds the 6EP1336-2BA00 SITOP POWER 20 supply, which feeds an automation cabinet DC distribution path at 24 V DC and 20 A.

Reading limit: system position only, not a wiring or safety drawing.

The documented AC input and DC output establish this conversion path.

Enlarged system diagram

A 120/230 V AC supply feeds the 6EP1336-2BA00 SITOP POWER 20 supply, which feeds an automation cabinet DC distribution path at 24 V DC and 20 A.

The documented AC input and DC output establish this conversion path.

View Mermaid source
flowchart LR
  ac["120/230 V AC supply"] -->|single-phase input| psu["6EP1336-2BA00 SITOP POWER 20"]
  psu -->|24 V DC at 20 A| bus["Automation cabinet DC distribution"]
View diagram labels
Nodes
120/230 V AC supply; 6EP1336-2BA00 SITOP POWER 20; Automation cabinet DC distribution
Edges
Single-phase AC input; 24 V DC at 20 A

Next action

The captured technical data sheet supports a 24 V DC, 20 A cabinet-supply role for this exact article.

Confirm the incoming-voltage selection and cabinet load before replacement.

Request help with this reference

Request help with this reference

Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.

Submission is unavailable until durable storage is verified.

Recovery request details
Add context only if useful
Optional updates
Recipient and data disclosure

Recipient and data disclosure

Named recipient: Ardkor human-qualification queue (internal local preview). No partner delivery is enabled here.

Data retained for this review: reference, selected route, location, technical context, contact details, consent state, and any accepted private attachment.

Response expectation: none is promised. If external routing is enabled later, the partner name, disclosed fields, and response expectation must be shown and accepted again.

Withdrawal and deletion: use the private request controls from the receipt to withdraw further processing or request access/deletion. The request remains recorded until the relevant Ardkor systems and any recipient confirm completion.

Read the privacy information before sending. For corrections, access, or deletion help, use the contact page or email reference@ardkor.org; mailbox delivery and attendance have not been verified.

This routing state is separate from watch, marketing, payment, and analytics choices. If no capable service match is found, the request remains a human-qualification lead and is never presented as provider acceptance. Ardkor is not an emergency or safety service and submission does not guarantee availability, price, repair, sourcing, or response.