6SE7034-6EE85-0AA0 Siemens MASTERDRIVES rectifier unit

Siemens identifies 6SE7034-6EE85-0AA0 as a MASTERDRIVES rectifier unit that supplies a common DC link to connected drive inverters.

System function and position

Rebuilt from individual evidence

Unknown: evidence boundary

Siemens identifies 6SE7034-6EE85-0AA0 as a MASTERDRIVES rectifier unit.

The Siemens manual lists 200 kW guide power, 463 A rated current, and 421 A base-load current for this exact unit.

At system level, it receives three-phase AC line input and supplies a common DC link to connected drive inverters; this position is an explicit inference from the cited facts.

Unknown: the individual unit's condition, installation, connected inverter set, and current commercial status.

Exact reference
6SE7034-6EE85-0AA0
Category
Drives / VFD
Evidence checked
2026-09-12

System role

This section explains what the product does and where it acts in the surrounding system.

Function
Supplies a common DC link from the three-phase AC line to connected drive inverters.
System position
Sits between the three-phase AC line input and the downstream MASTERDRIVES drive inverters.
Upstream / inputs
Receives the three-phase AC line input specified for the rectifier-unit system.
Downstream / outputs
Supplies DC-link power for connected drive inverters.
Limitations
Unknown: the individual unit's condition, installation, connected inverter set, and current commercial status.

Evidence ledger

Facts, inferences, and unknowns are kept separate.

Facts

  • Siemens identifies 6SE7034-6EE85-0AA0 as a MASTERDRIVES rectifier unit.

    Confidence: high

  • Siemens lists the rectifier unit with a guide power rating of 200 kW, rated current of 463 A, and base-load current of 421 A.

    Confidence: high

Inferences

  • Inferred system position: receives three-phase AC line input and supplies a common DC link to connected drive inverters.

    Confidence: high

    Rationale: The Siemens manual diagram and selection table place the rectifier unit between the line input and drive inverters; this system-position wording is an explicit inference.

Unknowns

  • Unknown: the individual unit's condition, installation, connected inverter set, and current commercial status.

    Confidence: low

    Missing evidence: The manufacturer manual does not inspect an individual unit or establish its installation-specific connections or commercial status.

System position diagram

Three-phase AC line passes through 6SE7034-6EE85-0AA0 rectifier to a common DC link.

Reading limit: system position only, not a wiring or safety drawing.

Evidence-supported conceptual system position for 6SE7034-6EE85-0AA0; this is not a wiring or safety instruction.

Enlarged system diagram

Three-phase AC line passes through 6SE7034-6EE85-0AA0 rectifier to a common DC link.

Evidence-supported conceptual system position for 6SE7034-6EE85-0AA0; this is not a wiring or safety instruction.

View Mermaid source
flowchart LR
  line["Three-phase AC line"] --> rect["6SE7034-6EE85-0AA0 rectifier"]
  rect --> dc["Common DC link"]
View diagram labels
Nodes
Three-phase AC line; 6SE7034-6EE85-0AA0 rectifier; Common DC link
Edges
AC supply; DC-link supply

Next action

Use the manufacturer-documented rectifier identity and ratings as the evidence-supported starting point, then verify the connected inverter set before service.

Unknown: confirm the individual unit's condition, installation, connected inverter set, and current commercial status before service or replacement.

Request help with this reference

Request help with this reference

Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.

Submission is unavailable until durable storage is verified.

Recovery request details
Add context only if useful
Optional updates
Recipient and data disclosure

Recipient and data disclosure

Named recipient: Ardkor human-qualification queue (internal local preview). No partner delivery is enabled here.

Data retained for this review: reference, selected route, location, technical context, contact details, consent state, and any accepted private attachment.

Response expectation: none is promised. If external routing is enabled later, the partner name, disclosed fields, and response expectation must be shown and accepted again.

Withdrawal and deletion: use the private request controls from the receipt to withdraw further processing or request access/deletion. The request remains recorded until the relevant Ardkor systems and any recipient confirm completion.

Read the privacy information before sending. For corrections, access, or deletion help, use the contact page or email reference@ardkor.org; mailbox delivery and attendance have not been verified.

This routing state is separate from watch, marketing, payment, and analytics choices. If no capable service match is found, the request remains a human-qualification lead and is never presented as provider acceptance. Ardkor is not an emergency or safety service and submission does not guarantee availability, price, repair, sourcing, or response.