The captured data sheet identifies 6SL3420-2TE11-7AA1 as a SINAMICS S120 double motor module. The data sheet specifies a 510-720 V DC link and maximum output current of 2 x 5.1 A.
System function and position
Rebuilt from individual evidence
The captured data sheet identifies 6SL3420-2TE11-7AA1 as a SINAMICS S120 double motor module.
The data sheet specifies a 510-720 V DC link and maximum output current of 2 x 5.1 A.
Sits between the shared SINAMICS S120 DC link and the two connected motor axes in the drive cabinet.
Unknown: installed topology, wiring, firmware, unit condition, and replacement compatibility for 6SL3420-2te11-7AA1 require separate evidence.
- Exact reference
- 6SL3420-2te11-7AA1
- Category
- Drives / VFD
- Evidence checked
- 2026-09-12
System role
This section explains what the product does and where it acts in the surrounding system.
- Function
- Drives two connected motor axes as a SINAMICS S120 power stage.
- System position
- Sits between the shared SINAMICS S120 DC link and the two connected motor axes in the drive cabinet.
- Upstream / inputs
- Receives DC-link energy and motion commands from the upstream SINAMICS S120 control path.
- Downstream / outputs
- Sends switched motor power to the two connected motor axes.
- Limitations
- Unknown: installed topology, wiring, firmware, unit condition, and replacement compatibility for 6SL3420-2te11-7AA1 require separate evidence.
Evidence ledger
Facts, inferences, and unknowns are kept separate.
Facts
The captured data sheet identifies 6SL3420-2TE11-7AA1 as a SINAMICS S120 double motor module.
- www.scribd.com — retrieved 2026-09-12; medium confidence
The data sheet specifies a 510-720 V DC link and maximum output current of 2 x 5.1 A.
- www.scribd.com — retrieved 2026-09-12; medium confidence
Inferences
Inferred system position: Sits between the shared SINAMICS S120 DC link and the two connected motor axes in the drive cabinet.
- www.scribd.com — retrieved 2026-09-12; medium confidence
Unknowns
Unknown: installed topology, wiring, firmware, unit condition, and replacement compatibility for 6SL3420-2te11-7AA1 require separate evidence.
System position diagram
View Mermaid source
flowchart LR
upstream["Upstream system"] --> item["6SL3420-2te11-7AA1"]
item --> downstream["Downstream drive system"]View diagram labels
- Nodes
- Upstream system; 6SL3420-2te11-7AA1; Downstream drive system
- Edges
- Documented input path; Documented output path
Request help with this reference
Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.