BMEXBP1002 Modicon X80 ten-slot Ethernet backplane

Schneider Electric ten-slot X80 Ethernet backplane for redundant power and in-rack modules.

System role

Rebuilt from individual evidence

Schneider Electric identifies BMEXBP1002 as a ten-slot Modicon X80 backplane with redundant Ethernet and power support.

The product page states that this backplane is used with Modicon M340, Modicon M580 and X80 modules and supports stable in-rack mounting.

The backplane provides the shared rack mounting and bus connection between the redundant power supplies, controller and installed X80 modules.

Exact reference
BMEXBP1002
Category
PLC / CPU
Evidence checked
2026-09-12

System role

This section explains what the product does and where it acts in the surrounding system.

Function
The backplane supplies the rack mounting and shared bus path for installed X80 modules.
System position
It sits between the rack power supplies and the controller or I/O modules installed in the ten available slots.
Upstream / inputs
Redundant rack power and module connections enter through the backplane.
Downstream / outputs
The backplane distributes rack bus connections to the installed M340, M580 or X80 modules.
Limitations
Unknown: the installed module mix, rack wiring and condition of an individual backplane.

Evidence ledger

Facts, inferences, and unknowns are kept separate.

Facts

  • Schneider Electric identifies BMEXBP1002 as a ten-slot Modicon X80 backplane with redundant Ethernet and power support.

    Confidence: high

    • www.se.com — retrieved 2026-09-12; high confidence
  • The product page states that this backplane is used with Modicon M340, Modicon M580 and X80 modules and supports stable in-rack mounting.

    Confidence: high

    • www.se.com — retrieved 2026-09-12; high confidence

Inferences

  • The backplane provides the shared rack mounting and bus connection between the redundant power supplies, controller and installed X80 modules.

    Confidence: medium

    Rationale: The documented product function and interfaces establish its position between the named upstream and downstream system stages.

    • www.se.com — retrieved 2026-09-12; high confidence

Unknowns

  • Unknown: the installed module mix, rack wiring and condition of an individual backplane.

    Confidence: low

    Missing evidence: The captured sources do not inspect the individual unit or its installation configuration.

System position diagram

BMEXBP1002 connects the controller with the field system in the documented signal path.

Reading limit: system position only, not a wiring or safety drawing.

The backplane provides the shared rack mounting and bus connection between the redundant power supplies, controller and installed X80 modules.

Enlarged system diagram

BMEXBP1002 connects the controller with the field system in the documented signal path.

The backplane provides the shared rack mounting and bus connection between the redundant power supplies, controller and installed X80 modules.

View Mermaid source
flowchart LR; Controller --> Module; Module --> Field
View diagram labels
Nodes
Controller; BMEXBP1002; Field system
Edges
Control data; Processed signal

Next action

The captured manufacturer evidence supports publishing BMEXBP1002 with the documented system role.

Unknown: the installed module mix, rack wiring and condition of an individual backplane.

Request help with this reference

Request help with this reference

Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.

Submission is unavailable until durable storage is verified.

Recovery request details
Add context only if useful
Optional updates
Recipient and data disclosure

Recipient and data disclosure

Named recipient: Ardkor human-qualification queue (internal local preview). No partner delivery is enabled here.

Data retained for this review: reference, selected route, location, technical context, contact details, consent state, and any accepted private attachment.

Response expectation: none is promised. If external routing is enabled later, the partner name, disclosed fields, and response expectation must be shown and accepted again.

Withdrawal and deletion: use the private request controls from the receipt to withdraw further processing or request access/deletion. The request remains recorded until the relevant Ardkor systems and any recipient confirm completion.

Read the privacy information before sending. For corrections, access, or deletion help, use the contact page or email reference@ardkor.org; mailbox delivery and attendance have not been verified.

This routing state is separate from watch, marketing, payment, and analytics choices. If no capable service match is found, the request remains a human-qualification lead and is never presented as provider acceptance. Ardkor is not an emergency or safety service and submission does not guarantee availability, price, repair, sourcing, or response.