BMXDDO6402K Modicon X80 64-channel digital output module

Schneider Electric X80 module for 64 positive-logic 24 V DC transistor outputs.

System role

Rebuilt from individual evidence

Schneider Electric identifies BMXDDO6402K as a Modicon X80 discrete output module with 64 positive-logic 24 V DC transistor outputs.

The Schneider Electric data sheet documents 0.1 A per output, 1.2 ms output response and protection against reverse polarity, short circuit, overload and overvoltage.

The module converts controller output commands into protected 24 V DC switching signals for field loads.

Exact reference
BMXDDO6402K
Category
PLC / CPU
Evidence checked
2026-09-12

System role

This section explains what the product does and where it acts in the surrounding system.

Function
The module switches 64 positive-logic 24 V DC transistor outputs.
System position
It sits between the Modicon controller output image and downstream DC field loads.
Upstream / inputs
The controller sends digital output commands through the Modicon rack bus.
Downstream / outputs
The module switches protected 24 V DC signals toward field actuators and indicators.
Limitations
Unknown: the load wiring, external fuses, output configuration and condition of an individual module.

Evidence ledger

Facts, inferences, and unknowns are kept separate.

Facts

  • Schneider Electric identifies BMXDDO6402K as a Modicon X80 discrete output module with 64 positive-logic 24 V DC transistor outputs.

    Confidence: high

    • www.se.com — retrieved 2026-09-12; high confidence
  • The Schneider Electric data sheet documents 0.1 A per output, 1.2 ms output response and protection against reverse polarity, short circuit, overload and overvoltage.

    Confidence: high

Inferences

  • The module converts controller output commands into protected 24 V DC switching signals for field loads.

    Confidence: medium

    Rationale: The documented product function and interfaces establish its position between the named upstream and downstream system stages.

Unknowns

  • Unknown: the load wiring, external fuses, output configuration and condition of an individual module.

    Confidence: low

    Missing evidence: The captured sources do not inspect the individual unit or its installation configuration.

System position diagram

BMXDDO6402K connects the controller with the field system in the documented signal path.

Reading limit: system position only, not a wiring or safety drawing.

The module converts controller output commands into protected 24 V DC switching signals for field loads.

Enlarged system diagram

BMXDDO6402K connects the controller with the field system in the documented signal path.

The module converts controller output commands into protected 24 V DC switching signals for field loads.

View Mermaid source
flowchart LR; Controller --> Module; Module --> Field
View diagram labels
Nodes
Controller; BMXDDO6402K; Field system
Edges
Control data; Processed signal

Next action

The captured manufacturer evidence supports publishing BMXDDO6402K with the documented system role.

Unknown: the load wiring, external fuses, output configuration and condition of an individual module.

Request help with this reference

Request help with this reference

Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.

Submission is unavailable until durable storage is verified.

Recovery request details
Add context only if useful
Optional updates
Recipient and data disclosure

Recipient and data disclosure

Named recipient: Ardkor human-qualification queue (internal local preview). No partner delivery is enabled here.

Data retained for this review: reference, selected route, location, technical context, contact details, consent state, and any accepted private attachment.

Response expectation: none is promised. If external routing is enabled later, the partner name, disclosed fields, and response expectation must be shown and accepted again.

Withdrawal and deletion: use the private request controls from the receipt to withdraw further processing or request access/deletion. The request remains recorded until the relevant Ardkor systems and any recipient confirm completion.

Read the privacy information before sending. For corrections, access, or deletion help, use the contact page or email reference@ardkor.org; mailbox delivery and attendance have not been verified.

This routing state is separate from watch, marketing, payment, and analytics choices. If no capable service match is found, the request remains a human-qualification lead and is never presented as provider acceptance. Ardkor is not an emergency or safety service and submission does not guarantee availability, price, repair, sourcing, or response.