Omron C200H-TS002 four-input temperature sensor unit
Evidence-backed reference for an Omron C200H temperature sensor unit with four thermocouple inputs.
Documented system function and position
Rebuilt from individual evidence
The Omron manual identifies C200H-TS002 as a four-input temperature sensor unit for selectable K or L thermocouples.
The unit converts the four temperature inputs into data transferred to the C200H CPU.
Its documented system position is between connected thermocouples and the PLC CPU.
Unknown: Installed unit number, sensor wiring, range settings, and PLC program compatibility require separate verification.
- Exact reference
- C200H-TS002
- Category
- PLC / CPU
- Evidence checked
- 2026-09-12
System role
This section explains what the product does and where it acts in the surrounding system.
- Function
- Measures temperatures from four selectable K or L thermocouple inputs for a C200H control system.
- System position
- Sits as a C200H special I/O unit between thermocouples and the PLC CPU.
- Upstream / inputs
- Receives signals from K (CA) or L (Fe-CuNi) thermocouples.
- Downstream / outputs
- Sends converted temperature data for the four inputs to the C200H CPU.
- Limitations
- Unknown: Installed unit number, sensor wiring, range settings, and PLC program compatibility require separate verification.
Evidence ledger
Facts, inferences, and unknowns are kept separate.
Facts
The Omron manual identifies C200H-TS002 as a temperature sensor unit with four inputs for selectable K (CA) or L (Fe-CuNi) thermocouples.
- www.omron.com.tw — retrieved 2026-09-12; high confidence
The manual documents conversion data for the four inputs and the transfer of that data from the temperature sensor unit to the C200H CPU.
- www.omron.com.tw — retrieved 2026-09-12; high confidence
Inferences
The unit sits in a C200H control system between connected thermocouples and the PLC CPU, converting temperature inputs into CPU data.
- www.omron.com.tw — retrieved 2026-09-12; high confidence
Unknowns
Unknown: Installed unit number, sensor wiring, range settings, and PLC program compatibility require separate verification.
System position diagram
View Mermaid source
flowchart LR
U["Upstream system"] -->|"Converted temperature data"| P["C200H-TS002"]
P -->|"Documented downstream path"| D["Downstream equipment"]View diagram labels
- Nodes
- Upstream system; C200H-TS002; Downstream equipment
- Edges
- Converted temperature data