Omron CQM1-PA216 documented industrial automation component

The power-supply unit converts the incoming AC supply into the power rails used by the CQM1H controller and its connected units. sits between the protected AC supply and the CQM1H controller backplane.

Documented system function

Rebuilt from individual evidence

System position and evidence limits

Omron documents CQM1-PA216 as an AC Power Supply Unit in the CQM1H programmable-controller system.

The power-supply unit converts the incoming AC supply into the power rails used by the CQM1H controller and its connected units.

The manual records switchable 80 to 138 VAC or 160 to 264 VAC input and 24 VDC, 0.5 A auxiliary output terminals for DC input units.

sits between the protected AC supply and the CQM1H controller backplane.

Unknown: installed voltage selection, load configuration, wiring condition, physical condition, and machine-specific compatibility are not established by the captured source.

Exact reference
CQM1-PA216
Category
PLC / CPU
Evidence checked
2026-09-12

System role

This section explains what the product does and where it acts in the surrounding system.

Function
The power-supply unit converts the incoming AC supply into the power rails used by the CQM1H controller and its connected units.
System position
sits between the protected AC supply and the CQM1H controller backplane.
Upstream / inputs
Receives the configured AC supply through the documented terminal block and protective earth connection.
Downstream / outputs
Supplies the CQM1H controller system and its DC input units through the documented power terminals.
Limitations
Unknown: installed voltage selection, load configuration, wiring condition, physical condition, and machine-specific compatibility are not established by the captured source.

Evidence ledger

Facts, inferences, and unknowns are kept separate.

Facts

  • Omron documents CQM1-PA216 as an AC Power Supply Unit in the CQM1H programmable-controller system.

    Confidence: high

  • The power-supply unit converts the incoming AC supply into the power rails used by the CQM1H controller and its connected units.

    Confidence: high

  • The manual records switchable 80 to 138 VAC or 160 to 264 VAC input and 24 VDC, 0.5 A auxiliary output terminals for DC input units.

    Confidence: medium

Inferences

  • Inferred system position: sits between the protected AC supply and the CQM1H controller backplane.

    Confidence: medium

    Rationale: The exact-reference identity and documented function support this system placement; installation-specific wiring is not asserted.

Unknowns

  • Unknown: installed voltage selection, load configuration, wiring condition, physical condition, and machine-specific compatibility are not established by the captured source.

    Confidence: low

    Missing evidence: The captured exact-reference sources do not establish the installed configuration, current unit condition, firmware, wiring, or machine-specific compatibility.

System position diagram

A system diagram shows Receives the configured AC supply through the documented terminal block and protective earth connection. feeding CQM1-PA216, which provides Supplies the CQM1H controller system and its DC input units through the documented power terminals..

Reading limit: system position only, not a wiring or safety drawing.

System position: sits between the protected AC supply and the CQM1H controller backplane.

Enlarged system diagram

A system diagram shows Receives the configured AC supply through the documented terminal block and protective earth connection. feeding CQM1-PA216, which provides Supplies the CQM1H controller system and its DC input units through the documented power terminals..

System position: sits between the protected AC supply and the CQM1H controller backplane.

View Mermaid source
flowchart LR\n  Upstream["Receives the configured AC supply through the documented terminal block and protective earth connection."] --> Item["CQM1-PA216"]\n  Item --> Downstream["Supplies the CQM1H controller system and its DC input units through the documented power terminals."]
View diagram labels
Nodes
Receives the configured AC supply through the documented terminal block and protective earth connection.; CQM1-PA216; Supplies the CQM1H controller system and its DC input units through the documented power terminals.
Edges
Documented upstream connection; Documented downstream function

Next action

Use the documented interfaces and ratings as the matching criteria before selecting this reference.

Confirm the exact marking, connected equipment, wiring, and operating conditions against the cited source before replacement or commissioning.

Request help with this reference

Request help with this reference

Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.

Submission is unavailable until durable storage is verified.

Recovery request details
Add context only if useful
Optional updates
Recipient and data disclosure

Recipient and data disclosure

Named recipient: Ardkor human-qualification queue (internal local preview). No partner delivery is enabled here.

Data retained for this review: reference, selected route, location, technical context, contact details, consent state, and any accepted private attachment.

Response expectation: none is promised. If external routing is enabled later, the partner name, disclosed fields, and response expectation must be shown and accepted again.

Withdrawal and deletion: use the private request controls from the receipt to withdraw further processing or request access/deletion. The request remains recorded until the relevant Ardkor systems and any recipient confirm completion.

Read the privacy information before sending. For corrections, access, or deletion help, use the contact page or email reference@ardkor.org; mailbox delivery and attendance have not been verified.

This routing state is separate from watch, marketing, payment, and analytics choices. If no capable service match is found, the request remains a human-qualification lead and is never presented as provider acceptance. Ardkor is not an emergency or safety service and submission does not guarantee availability, price, repair, sourcing, or response.