TBXDSS1625 - Schneider Electric TBX7 relay output module
Schneider Electric TBX7 relay output module with a documented system role and explicit evidence boundaries.
Documented function
Rebuilt from individual evidence
System position
Unknown: Evidence boundary
Schneider Electric identifies TBXDSS1625 as a TBX7 16 relay-output 24 VDC reference.
The Modicon Premium catalog extract lists TBX DSS 1625 as a 16-channel relay output module with 50 VA relay output characteristics.
Schneider Electric records TBXDSS1625 as discontinued on June 30, 2006, with standard service ending June 30, 2014.
The module sits in the TBX remote I/O path between PLC output commands and relay-controlled field actuators.
Unknown: The installed PLC, relay contact loads, wiring, protection, and replacement condition are not established by the captured sources.
- Exact reference
- TBXDSS1625
- Category
- PLC / CPU
- Evidence checked
- 2026-09-12
System role
This section explains what the product does and where it acts in the surrounding system.
- Function
- Switches relay outputs commanded by the PLC toward field actuators.
- System position
- Sits in the TBX remote I/O path between PLC output commands and relay-controlled field actuators.
- Upstream / inputs
- Receives output commands from the PLC over the TBX architecture.
- Downstream / outputs
- Switches relay channels for downstream field actuators.
- Limitations
- Unknown: The installed PLC, relay contact loads, wiring, protection, and replacement condition are not established by the captured sources.
Evidence ledger
Facts, inferences, and unknowns are kept separate.
Facts
Schneider Electric identifies TBXDSS1625 as a TBX7 16 relay-output 24 VDC reference.
- www.se.com — retrieved 2026-09-12; high confidence
The Modicon Premium catalog extract lists TBX DSS 1625 as a 16-channel relay output module with 50 VA relay output characteristics.
- www.scribd.com — retrieved 2026-09-12; medium confidence
Schneider Electric records TBXDSS1625 as discontinued on June 30, 2006, with standard service ending June 30, 2014.
- www.se.com — retrieved 2026-09-12; high confidence
Inferences
The module sits in the TBX remote I/O path between PLC output commands and relay-controlled field actuators.
- www.se.com — retrieved 2026-09-12; high confidence
- www.scribd.com — retrieved 2026-09-12; medium confidence
Unknowns
Unknown: The installed PLC, relay contact loads, wiring, protection, and replacement condition are not established by the captured sources.
System position diagram
View Mermaid source
flowchart LR
upstream["Modicon Premium PLC"] --> item["TBXDSS1625"]
item --> downstream["Relay-controlled field actuators"]View diagram labels
- Nodes
- Modicon Premium PLC; TBXDSS1625; Relay-controlled field actuators
- Edges
- Documented upstream connection; Documented downstream function
Request help with this reference