TBXSAP10 - Schneider Electric TBX FIPIO and AS-i gateway
Schneider Electric TBX FIPIO and AS-i gateway with a documented system role and explicit evidence boundaries.
Documented function
Rebuilt from individual evidence
System position
Unknown: Evidence boundary
Schneider Electric identifies TBXSAP10 as a gateway module for an AS-i line and FIPIO.
The TBX SAP 10 guide states that the gateway connects the AS-i sensor-actuator bus through FIPIO to TSX model 40, APRIL 5000, and Premium PLCs and decentralizes I/O.
The gateway sits between the AS-i sensor-actuator bus and the PLC over the FIPIO network.
Unknown: The connected AS-i slaves, FIPIO address, PLC program, bus power, and site-specific wiring are not established by the captured sources.
- Exact reference
- TBXSAP10
- Category
- PLC / CPU
- Evidence checked
- 2026-09-12
System role
This section explains what the product does and where it acts in the surrounding system.
- Function
- Routes AS-i sensor and actuator data to and from the PLC through FIPIO.
- System position
- Sits between the AS-i sensor-actuator bus and the PLC over the FIPIO network.
- Upstream / inputs
- Receives cyclic data from AS-i sensors and actuators.
- Downstream / outputs
- Exchanges the AS-i I/O image with the connected PLC over FIPIO.
- Limitations
- Unknown: The connected AS-i slaves, FIPIO address, PLC program, bus power, and site-specific wiring are not established by the captured sources.
Evidence ledger
Facts, inferences, and unknowns are kept separate.
Facts
Schneider Electric identifies TBXSAP10 as a gateway module for an AS-i line and FIPIO.
- www.se.com — retrieved 2026-09-12; high confidence
The TBX SAP 10 guide states that the gateway connects the AS-i sensor-actuator bus through FIPIO to TSX model 40, APRIL 5000, and Premium PLCs and decentralizes I/O.
- manualzz.com — retrieved 2026-09-12; medium confidence
Inferences
The gateway sits between the AS-i sensor-actuator bus and the PLC over the FIPIO network.
- www.se.com — retrieved 2026-09-12; high confidence
- manualzz.com — retrieved 2026-09-12; medium confidence
Unknowns
Unknown: The connected AS-i slaves, FIPIO address, PLC program, bus power, and site-specific wiring are not established by the captured sources.
System position diagram
View Mermaid source
flowchart LR
upstream["AS-i sensor-actuator bus"] --> item["TBXSAP10"]
item --> downstream["FIPIO-connected PLC"]View diagram labels
- Nodes
- AS-i sensor-actuator bus; TBXSAP10; FIPIO-connected PLC
- Edges
- Documented upstream connection; Documented downstream function
Request help with this reference
Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.