Schneider Electric TSXDSY64T2K 64-channel solid-state output module

The captured Schneider Electric data sheet identifies TSXDSY64T2K as a Modicon Premium 64-channel protected solid-state output module. The data sheet records 24 V DC positive outputs, 0.1 A per channel, 5 A maximum module current, 1.2 ms response, and four HE-10 connectors for TSXDSY64T2K.

Documented system function and position

Rebuilt from individual evidence

The captured Schneider Electric data sheet identifies TSXDSY64T2K as a Modicon Premium 64-channel protected solid-state output module.

The data sheet records 24 V DC positive outputs, 0.1 A per channel, 5 A maximum module current, 1.2 ms response, and four HE-10 connectors for TSXDSY64T2K.

Sits between the Premium PLC output image and field actuators in the machine control chain.

Unknown: actuator type, cabinet wiring, current lifecycle status, and installation-specific thermal conditions are not established by the cited data sheet.

Exact reference
TSXDSY64T2K
Category
PLC / CPU
Evidence checked
2026-09-12

System role

This section explains what the product does and where it acts in the surrounding system.

Function
Switches 24 V DC machine output loads from the Premium PLC output image.
System position
Sits between the Premium PLC output image and field actuators in the machine control chain.
Upstream / inputs
Receives output commands from the Premium PLC and the documented 24 V DC supply.
Downstream / outputs
Switches the connected field actuators through its solid-state output channels.
Limitations
Unknown: actuator type, cabinet wiring, current lifecycle status, and installation-specific thermal conditions are not established by the cited data sheet.

Evidence ledger

Facts, inferences, and unknowns are kept separate.

Facts

  • The captured Schneider Electric data sheet identifies TSXDSY64T2K as a Modicon Premium 64-channel protected solid-state output module.

    Confidence: high

  • The data sheet records 24 V DC positive outputs, 0.1 A per channel, 5 A maximum module current, 1.2 ms response, and four HE-10 connectors for TSXDSY64T2K.

    Confidence: high

Inferences

  • Sits between the Premium PLC output image and field actuators in the machine control chain.

    Confidence: medium

    Rationale: The documented product function and interface establish the adjacent system stages.

Unknowns

  • Unknown: actuator type, cabinet wiring, current lifecycle status, and installation-specific thermal conditions are not established by the cited data sheet.

    Confidence: low

    Missing evidence: actuator type, cabinet wiring, current lifecycle status, and installation-specific thermal conditions are not established by the cited data sheet.

System position diagram

A flow from Receives output commands from the Premium PLC and the documented 24 V DC supply. through TSXDSY64T2K to Switches the connected field actuators through its solid-state output channels..

Reading limit: system position only, not a wiring or safety drawing.

System position inferred from the cited evidence: Sits between the Premium PLC output image and field actuators in the machine control chain.

Enlarged system diagram

A flow from Receives output commands from the Premium PLC and the documented 24 V DC supply. through TSXDSY64T2K to Switches the connected field actuators through its solid-state output channels..

System position inferred from the cited evidence: Sits between the Premium PLC output image and field actuators in the machine control chain.

View Mermaid source
flowchart LR
  upstream["Receives output commands from the Premium PLC and the documented 24 V DC supply."] -->|"documented input"| item["TSXDSY64T2K"]
  item -->|"documented output"| downstream["Switches the connected field actuators through its solid-state output channels."]
View diagram labels
Nodes
Receives output commands from the Premium PLC and the documented 24 V DC supply.; Schneider Electric TSXDSY64T2K 64-channel solid-state output module; Switches the connected field actuators through its solid-state output channels.
Edges
Documented upstream interface; Documented downstream interface

Next action

Use TSXDSY64T2K when the actuator load, voltage, current, and HE-10 wiring match the captured data sheet.

Unknown: Confirm the exact marking, interfaces, processor configuration, and installation fit before replacement or commissioning.

Request help with this reference

Request help with this reference

Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.

Submission is unavailable until durable storage is verified.

Recovery request details
Add context only if useful
Optional updates
Recipient and data disclosure

Recipient and data disclosure

Named recipient: Ardkor human-qualification queue (internal local preview). No partner delivery is enabled here.

Data retained for this review: reference, selected route, location, technical context, contact details, consent state, and any accepted private attachment.

Response expectation: none is promised. If external routing is enabled later, the partner name, disclosed fields, and response expectation must be shown and accepted again.

Withdrawal and deletion: use the private request controls from the receipt to withdraw further processing or request access/deletion. The request remains recorded until the relevant Ardkor systems and any recipient confirm completion.

Read the privacy information before sending. For corrections, access, or deletion help, use the contact page or email reference@ardkor.org; mailbox delivery and attendance have not been verified.

This routing state is separate from watch, marketing, payment, and analytics choices. If no capable service match is found, the request remains a human-qualification lead and is never presented as provider acceptance. Ardkor is not an emergency or safety service and submission does not guarantee availability, price, repair, sourcing, or response.