Schneider Electric VW3A3310D Modbus TCP Ethernet communication card
Schneider documentation identifies VW3A3310D as a Modbus TCP communication card for Altivar 61 and Altivar 71 drives. The card has dual RJ45 Ethernet connectors for daisy-chain networking and supports drive configuration, control, monitoring, and diagnostics.
Documented system function and position
Rebuilt from individual evidence
Schneider documentation identifies VW3A3310D as a Modbus TCP communication card for Altivar 61 and Altivar 71 drives.
The card has dual RJ45 Ethernet connectors for daisy-chain networking and supports drive configuration, control, monitoring, and diagnostics.
Sits between the Altivar drive control interface and the Ethernet network.
Unknown: installed wiring, firmware, condition, and installation-specific compatibility are not established by the captured sources.
- Exact reference
- VW3A3310D
- Category
- Drives / VFD
- Evidence checked
- 2026-09-12
System role
This section explains what the product does and where it acts in the surrounding system.
- Function
- Routes Modbus TCP data between an Altivar drive and the Ethernet control network.
- System position
- Sits between the Altivar drive control interface and the Ethernet network.
- Upstream / inputs
- Receives drive control, status, and diagnostic data from the Altivar drive.
- Downstream / outputs
- Exchanges Modbus TCP data with the downstream Ethernet control network.
- Limitations
- Unknown: installed wiring, firmware, condition, and installation-specific compatibility are not established by the captured sources.
Evidence ledger
Facts, inferences, and unknowns are kept separate.
Facts
Schneider documentation identifies VW3A3310D as a Modbus TCP communication card for Altivar 61 and Altivar 71 drives.
- ckm-content.se.com — retrieved 2026-09-12; high confidence
The card has dual RJ45 Ethernet connectors for daisy-chain networking and supports drive configuration, control, monitoring, and diagnostics.
- ckm-content.se.com — retrieved 2026-09-12; high confidence
- www.se.com — retrieved 2026-09-12; high confidence
Routes Modbus TCP data between an Altivar drive and the Ethernet control network.
- ckm-content.se.com — retrieved 2026-09-12; high confidence
Inferences
Inferred system position: Sits between the Altivar drive control interface and the Ethernet network.
- ckm-content.se.com — retrieved 2026-09-12; high confidence
Unknowns
Unknown: installed wiring, firmware, condition, and installation-specific compatibility are not established by the captured sources.
System position diagram
View Mermaid source
flowchart LR
upstream["Receives drive control, status, and diagnostic data from the Altivar drive."] -->|documented path| item["VW3A3310D"]
item -->|documented path| downstream["Exchanges Modbus TCP data with the downstream Ethernet control network."]View diagram labels
- Nodes
- Receives drive control, status, and diagnostic data from the Altivar drive.; Schneider Electric VW3A3310D Modbus TCP Ethernet communication card; Exchanges Modbus TCP data with the downstream Ethernet control network.
- Edges
- Documented upstream path; Documented downstream path
Request help with this reference
Provide the exact reference, machine context, and observed symptom so the next review can stay evidence-based.
