Category hub / PLC / CPU

PLC and CPU references - identify, recover, replace

A PLC or CPU reference is only useful when it stays connected to its rack, firmware, safety role, and machine context. This hub starts with the reference itself, then records what is known before a source, repair, exchange, or replacement decision is made.

PLC / CPU / field guide and catalog statecomplete

Catalogue references

537 catalogue references

537 catalogue references.

PLC / CPU catalogue search results
RankReferenceManufacturerTypeSystem roleEvidenceStatusAction
513VL3725-1AA46-0AA0Not statedNot statedThe VL molded-case circuit breaker protects and switches a three-phase feeder against documented overload and short-circuit conditions.Individual researchPUBLISHEDOpen reference
523VL5750-1DC36Not statedNot statedThe VL630N molded-case circuit breaker protects and switches a three-phase feeder against documented overload and short-circuit conditions.Individual researchPUBLISHEDOpen reference
533VL5763-1DC36-0AA0Not statedNot statedThe VL630N molded-case circuit breaker protects and switches a three-phase feeder against documented overload and short-circuit conditions.Individual researchPUBLISHEDOpen reference
543VL9800-3MQ00Not statedNot statedThe VL load disconnector isolates and switches a low-voltage feeder between an upstream source and a protected circuit.Individual researchPUBLISHEDOpen reference
553VT9200-3MN00Not statedNot statedThe SENTRON motorized operating mechanism drives a compatible circuit-breaker mechanism from its control supply.Individual researchPUBLISHEDOpen reference
563WL1110-3EB37-5FA4-ZR10Not statedNot statedThe 3WL air circuit breaker protects and switches a high-current incoming or feeder circuit.Individual researchPUBLISHEDOpen reference
573WL1116-3FB37-5FA4-ZNot statedNot statedThe 3WL air circuit breaker protects and switches a high-current incoming or feeder circuit.Individual researchPUBLISHEDOpen reference
583WL1350-4FB36-5FR4Not statedNot statedThe SENTRON air circuit breaker protects and switches a high-current plant or motor feeder.Individual researchPUBLISHEDOpen reference
59440R-H23176Not statedNot statedThe MSR210 safety relay monitors dual-channel safety inputs and switches safety outputs for a machine control circuit.Individual researchPUBLISHEDOpen reference
60499-NOH-00510Not statedNot statedThe Schneider Automation hub routes Ethernet frames between copper and fiber network segments.Individual researchPUBLISHEDOpen reference
614AM3242-5CT10-0FA0Not statedNot statedThe SITAS control transformer converts a 440 V control supply to an isolated 230 V single-phase control supply.Individual researchPUBLISHEDOpen reference
624AM3442-8DD40-0FA0Not statedNot statedThe SITAS control transformer converts a selectable primary supply to an isolated single-phase control supply.Individual researchPUBLISHEDOpen reference
63505-6660BNot statedNot statedThe power supply supplies rack power for a Series 505 PLC chassis.Individual researchPUBLISHEDOpen reference
64505-7012ANot statedNot statedThe analog I/O module routes analog field signals between a TI 505 PLC and connected devices.Individual researchPUBLISHEDOpen reference
655069-L320ERNot statedNot statedThe controller executes CompactLogix control logic for connected I/O and EtherNet/IP devices.Individual researchPUBLISHEDOpen reference
665069-L340ERNot statedNot statedThe controller executes CompactLogix control logic for connected I/O and EtherNet/IP devices.Individual researchPUBLISHEDOpen reference
676AG1123-2GB03-2AX0Not statedNot statedThe HMI displays machine information and provides the operator-facing control surface in the PROFINET automation system.Individual researchPUBLISHEDOpen reference
686AG1132-4HB01-2AB0Not statedNot statedThe module switches relay-controlled loads from a distributed I/O station.Individual researchPUBLISHEDOpen reference
696AG1138-4FA04-2AB0Not statedNot statedThe module receives safety-related digital input signals from field devices in a distributed safety I/O station.Individual researchPUBLISHEDOpen reference
706AG1138-4FB04-2AB0Not statedNot statedThe module switches safety-related output loads from a distributed safety I/O station.Individual researchPUBLISHEDOpen reference
716AG1243-1BX30-2AX0Not statedNot statedThe communications processor routes an additional Ethernet connection from a SIMATIC S7-1200 to control centers using documented telecontrol protocols.Individual researchPUBLISHEDOpen reference
726AG1332-5HB01-2AB0Not statedNot statedThe module converts S7-300 output commands into isolated analog voltage or current signals for field equipment.Individual researchPUBLISHEDOpen reference
736AG1503-2CA01-2AA0Not statedNot statedThe optical link module routes PROFIBUS communication across optical and electrical network segments.Individual researchPUBLISHEDOpen reference
746AG1521-1BH00-7AB0Not statedNot statedThe module receives 24 V DC digital field signals for processing by an S7-1500 control system.Individual researchPUBLISHEDOpen reference
756AG1521-1BL00-7AB0Not statedNot statedThe module receives 24 V DC digital field signals for processing by an S7-1500 control system.Individual researchPUBLISHEDOpen reference
766AG1522-1BH01-7AB0Not statedNot statedThe module switches 24 V DC digital actuator signals from an S7-1500 control system.Individual researchPUBLISHEDOpen reference
776AG1647-0AD11-2AX0Not statedNot statedThe HMI displays machine information and provides the operator-facing control surface for the connected automation system.Individual researchPUBLISHEDOpen reference
786AG1972-0DA00-2AA0Not statedNot statedSupplies the termination point for the RS485 PROFIBUS segment.Individual researchPUBLISHEDOpen reference
796AU1400-1PA22-0AA0Not statedNot statedThe CF card supplies the listed removable storage medium for the SIMOTION D410-2 motion controller.Individual researchPUBLISHEDOpen reference
806AU1400-2KA00-0CA0Not statedNot statedThe CF card supplies the listed removable storage medium for the SIMOTION D4x5 motion controller.Individual researchPUBLISHEDOpen reference
816AU1400-2PA00-0AA0Not statedNot statedThe CF card supplies the listed removable storage medium for the SIMOTION D4xx motion controller.Individual researchPUBLISHEDOpen reference
826AU1400-2PA02-0AA0Not statedNot statedStores the documented SIMOTION kernel and SINAMICS drive software on a D4xx CompactFlash card.Individual researchPUBLISHEDOpen reference
836AU1400-2PA22-0AA0Not statedNot statedControls firmware storage by carrying the D4x5-2 kernel, SINAMICS firmware and controller data on the SIMOTION CompactFlash card.Individual researchPUBLISHEDOpen reference
846AU1425-2AD00-0AA0Not statedNot statedExecutes programmable motion-control tasks and exchanges machine signals with connected drives and field devices.Individual researchPUBLISHEDOpen reference
856AU1435-2AA00-0AA0Not statedNot statedExecutes programmable motion control and coordinates connected drives through the SIMOTION D435-2 controller interfaces.Individual researchPUBLISHEDOpen reference
866DD1607-0EA2Not statedNot statedRoutes SIMOLINK communication through two integrated SLB interfaces for an FM458 application module.Individual researchPUBLISHEDOpen reference
876DD1660-0AH1Not statedNot statedRoutes communication for compatible SIMOVERT P 6SE12 and SIMOREG K 6RA24 systems.Individual researchPUBLISHEDOpen reference
886DD1660-0BF0Not statedNot statedStores and buffers global data in a SIMATIC TDC distributed-control system using 2 MB SRAM.Individual researchPUBLISHEDOpen reference
896DD1660-0BH0Not statedNot statedRoutes GDM communication through one 640 Mbps fiber-optic interface.Individual researchPUBLISHEDOpen reference
906DD1661-0AB1Not statedNot statedRoutes SINEC H1 network communication and exchanges data with SIMADYN D CPU modules through dual-port RAM.Individual researchPUBLISHEDOpen reference
916DD1661-0AE1Not statedNot statedRoutes TCP/IP or UDP communication through an RJ45 Industrial Ethernet interface and the TDC L/C bus.Individual researchPUBLISHEDOpen reference
926DD1662-0AB0Not statedNot statedRoutes serial communication for supported SS4, SS5 and SS52 modules using DUST, USS or PROFIBUS protocols.Individual researchPUBLISHEDOpen reference
936DD1662-0AC0Not statedNot statedRoutes CAN, DeviceNet or PROFIBUS communication for supported communication modules through two module slots and the L bus.Individual researchPUBLISHEDOpen reference
946DD1681-0BF1Not statedNot statedProtects the SIMADYN D interface layer with a passive surge-suppression circuit.Individual researchPUBLISHEDOpen reference
956DD1681-0EB3Not statedNot statedIsolates and converts eight binary 24 or 48 V DC signals to SIMADYN D, SIMATIC TDC or FM458 signal levels.Individual researchPUBLISHEDOpen reference
966DD1682-0AJ1Not statedNot statedProtects an unused slot opening by covering one blank position in a SIMADYN D digital-control SR6 subrack.Individual researchPUBLISHEDOpen reference
976DD1682-0BC4Not statedNot statedSupplies and hosts SIMADYN D modules through a 12-slot subrack with an integrated 115 or 230 V AC power supply and L/C buses.Individual researchPUBLISHEDOpen reference
986DD1682-0CF0Not statedNot statedSupplies and houses SIMADYN D PT10 and CS51 PC boards in a fanless 115 or 230 V switchable technology box.Individual researchPUBLISHEDOpen reference
996DD1682-0CG0Not statedNot statedSupplies and hosts up to two T400 boards or one T400 board with a MASTERDRIVES communication board for drive control.Individual researchPUBLISHEDOpen reference
1006DD1682-0CH2Not statedNot statedSupplies and hosts SIMATIC TDC modules in a 21-slot rack boundary with an integrated fan for GDM use.Individual researchPUBLISHEDOpen reference

Return to the parts index or submit a reference for review.

What this category covers

Central CPUs, fail-safe CPUs, racks, and distributed-I/O control roles

Reference identity, successor checks, firmware and network context

Evidence needed before repair, exchange, or a compatible replacement

Integration status: 16 catalogue identities integrated; identity pages are indexable and optional evidence is omitted when unavailable

Choose a recovery path

Editorial queue

9 draft / 1 published

Published guides passed the shared evidence evaluator. Draft entries remain noindex until their body, sources, review window, provenance, and category path pass the same gates.

IntentQuestionSummarySource notesIntegrationPreview
How to identify a PLC CPU from its nameplateWhich nameplate fields prove a PLC CPU identity?A practical intake sequence for the reference, revision, family, and visible condition.docs/data/v1-guide-publication-review.md; Siemens SIMATIC S7-1200 system manual V4.5: https://cache.industry.siemens.com/dl/files/241/109797241/att_1066673/v1/s71200_system_manual_en-US_en-US.pdf; Siemens 6ES7214-1AG40-0XB0 product data: https://mall.industry.siemens.com/goos/catalog/Pages/mmpdata.ashx?MLFB1=6ES7214-1AG40-0XB0&lang=en; Siemens 6ES7214-1BG40-0XB0 product data: https://mall.industry.siemens.com/goos/catalog/Pages/mmpdata.ashx?MLFB1=6ES7214-1BG40-0XB0&lang=enPUBLISHED - INDEXABLEOpen published guide
PLC CPU or I/O module: what is the difference?How can a technician tell the controller from an I/O module?Explain the control role and the evidence that separates a CPU from its connected modules.docs/data/data-model.md; Manufacturer documentation required before publicationDRAFT - NOT INDEXABLEOpen draft
What to record before recovering a fail-safe PLC CPUWhat safety and configuration evidence is needed before recovery?Define a safe intake boundary for a fail-safe controller without promising compatibility.docs/product/comparison-and-recovery-model.md; Qualified technical evidence requiredDRAFT - NOT INDEXABLEOpen draft
How to check a PLC CPU successor referenceWhat must be compared before accepting a successor?A comparison checklist for hardware, firmware, safety, wiring, and project constraints.docs/data/data-model.md; Manufacturer documentation required before publicationDRAFT - NOT INDEXABLEOpen draft
Why network context matters for a PLC CPUWhich network details affect a CPU replacement?Show why a part number alone cannot confirm a drop-in replacement in a control network.docs/product/comparison-and-recovery-model.md; Qualified technical evidence requiredDRAFT - NOT INDEXABLEOpen draft
Planning around an obsolete PLC CPUWhat should be documented when a PLC CPU is obsolete?Separate evidence gathering, machine risk, sourcing, and migration decisions.docs/data/data-management.md; Current manufacturer status requiredDRAFT - NOT INDEXABLEOpen draft
PLC repair or replacement: which evidence helps?When is repair evidence more useful than a replacement quote?Frame the recovery decision around symptoms, downtime, configuration, and available evidence.docs/product/comparison-and-recovery-model.md; Repair capability evidence requiredDRAFT - NOT INDEXABLEOpen draft
A control-cabinet checklist for PLC identificationWhat should be photographed during a PLC cabinet audit?List the cabinet and machine context that makes a reference request actionable./how-it-works/#request-checklist; Technical evidence requiredDRAFT - NOT INDEXABLEOpen draft
PLC reference aliases and formattingWhy do the same PLC references appear in different formats?Document normalization without treating an alias as proof of product identity.docs/data/data-model.md; Source evidence requiredDRAFT - NOT INDEXABLEOpen draft
What evidence to send with a PLC requestWhich files and photos make a PLC request useful?A short evidence pack for reference, symptom, machine, and desired recovery route./how-it-works/#request-checklist; Ardkor intake policyDRAFT - NOT INDEXABLEOpen draft

Have better evidence?

Send the exact reference, photos, symptom, and machine context. The category stays useful while each product and article is reviewed separately.

Submit a reference